Article  
Direct Steam Production in Focus: Solar Energy Stations  
1,  
2,  
Noor Al-Bandar *  
and Ahmed Hamza Osman  
1
Department of Electrical, Electronic and Systems Engineering, Faculty of Engineering and Built Environment,  
Universiti Kebangsaan Malaysia, UKM, Bangi 43600, Selangor, Malaysia; p117813@siswa.ukm.edu.my  
Department of Information Systems, Faculty of Computing and Information Technology in Rabigh, King Ab-  
dulaziz University, 21911, Saudi Arabia; ahoahmad@kau.edu.sa  
2
*
Correspondence: p117813@siswa.ukm.edu.my  
Abstract: A modeling method was created to forecast the efficiency of a focusing solar energy facil-  
ity using direct steam production (DSP) method. We developed a comprehensive DSP solar field  
model for parabolic troughs (PTC) and linear Fourier collector in MATLAB. The predictions of the  
model had been assessed against operational information from the first precommercial 10 MW DSP  
solar power station, intended for a government initiative. The station efficiency was examined in  
dual ways: “fixed” and “sliding” steam turbine intake flow.  
Keywords: Focused solar energy; Straight Combustion Production; Capacity analysis; Modeling  
1. Introduction  
Results from government-funded studies indicate that DSP is a compelling technical  
alternative for focusing solar power generation [1]. Utilizing water and steam for both the  
solar field and the power block has various advantages over the existing CSP method that  
use parabolic trough collectors with synthetic oil as the heat transfer fluid. The steam heat  
threshold of around 399°C for contemporary artificial oils can be surpassed. An efficient  
temperature of 450°C appears to be viable for next-generation receiving containers, hence  
enhancing the potential for overall efficacy.  
In addition, the elimination of oil and water radiators is feasible if water is immedi-  
ately drained and heated in the solar field [2], leading to a more straightforward plant  
architecture and reduced capital expenditures. The utilization of demineralized water is  
considered environmentally benign: in contrast to oil, water is more economical, environ-  
mentally friendly, and non-flammable.  
In comparison to liquid salt, water is both more economical and less caustic. Among  
DSP that related interest issues, the adhering to essential challenges are the the majority  
pertinent [3-5]:  
Citation: Al-Bandar, N. and Os-  
man, A. H., Direct Steam Production  
in Focus: Solar Energy Stations. 2026.  
4. p. 2-8  
Academic Editor: Asst. Prof. Wurod  
Qasim Mohamed  
Firstly, the equilibrium of the circular liquid within each tube is essential to enable  
interior chilling of the exterior walls, hence eliminating areas of heat. The skeletal strength  
of absorbers tubes and the links between enthusiasts and absorption tubes at extreme  
pressure and high temperatures. Subsequently, implement station management systems,  
especially during transitional phases of irradiation. Ultimately, connection with storage  
facilities tailored to the unique properties of the dual-phase fluid water and steam occurs  
in the evaporating portion, while the initial heating and overheating components can be  
managed by traditional two tank hot salt storage methods.  
The expertise and knowledge gained from the work were utilized in the Iraqi gov-  
ernment's initiative to develop the inaugural precommercial DSP station. The system con-  
sists of a parabolic trough solar sector linked to a heated steam The actress cycle operating  
at 399°C and 70 bar, with a nominal output of electricity of 10 MW. This research proposes  
the use of modeling for modeling a DSG plant that generates steam from superheated air.  
Received: 5/1/2026  
Revised: 10/2/2026  
Accepted: 8/3/2026  
Published: 12/3/2026  
Copyright: © 2026 by the authors.  
Submitted for possible open access  
publication under the terms and  
conditions of the Creative Commons  
Attribution (CC BY) license  
s/by/4.0/).  
EJEEE 2026  
2 of 8  
The data collected from the government program has been utilized as a guide because to  
the scarcity of details on current DSP deployments. Attention has been directed on pro-  
ducing electricity via the steam turbine, with variations in inlet pressure management  
over a 24-month duration.  
2. Materials and Methods  
2.1 Installation of DSP Station  
Figure 1 illustrates the configuration utilized in the current investigation. This per-  
tains to the government DSP solar energy station with an authorized capacity of 10 MW,  
for which conceptual viability was evaluated in [6-8]. The PTC solar area has 8 parallel-  
connected loops, each containing 9 solar arrays. A single loop of readers has 10 readers  
designated for getting ready and evaporated, while the final two readers are allocated for  
overheating. A separation device with an exit water rating of 0.9 is positioned between  
the evaporator unit and the superheater in order to ensure adequate cooling of the ab-  
sorber’s tubes in continuous operation. Recirculating and injecting valves are employed  
to enhance management of the solar field exit heat. Table 1 delineates the design aspects  
of the PTC [9]. Regarding the power block as illustrated in Table 2, the steam pressure and  
temperature at the turbine inlet are established at 70 bar and 350°C, correspondingly. Due  
to the plant's limited dimensions, a solitary steam obtaining range, with a pressure limit  
of 3.1 bar to 6.1 bar, was included to supply a deaerator. The air-cooled condenser was  
evaluated with a design maximum pressure for operation of 0.2 bar.  
Table 1. Photovoltaic radiation characteristics  
Table 2. Specifications for the energy unit.  
A particular collector's total length (m)  
99  
Pressure and temperature at turbine inlet  
Pressure and temperature at solar field inlet  
Deaerator pressure (bar)  
78bar-380°C  
Each receiver's gross collectors’ size (m2)  
Iron isolator tube's outside perimeter (m)  
Iron absorbers tube with inner diameter (m)  
The quantity of 90° angles  
623  
93bar-170°C  
0.082  
0.061  
4
7.2  
0.192  
82/91  
6.3  
Condenser pressure (bar)  
HP/LP Turbine isentropic efficiency (%)  
Gross power (MW)  
The degree of roughness of the isolator tube  
Maximum refractive effectiveness  
8.59*10-4  
0.901  
15  
Net power (MW)  
6
Tension decreases in the sun radiation (bar)  
Net electric efficiency (%)  
24.1  
Two distinct ways to operate for a steam turbine were evaluated: the first, termed  
“sliding pressure,” entails an inverse variation of the turbine inlet pressure with the steam  
flow rate, while the second, referred to as “throttle mode,” maintains an unchanged tur-  
bine entry pressure equal to 70 bar, despite a steam flow rate entering the turbine that is  
below the design specification. Additionally, steam from exhaust parameters were metic-  
ulously computed, considering kinetic expenses as an effect of the emission volumetric  
flow Figure 2. The emission waste graph is a causal relationship for an entropy differential  
known as combustion waste (CW). When applied to the entropy at the expanding path  
conclusion (EPC), it enables the accurate calculation of turbine power per mass unit (W)  
as follows [10]:  
(
)
( )  
1
푊 = ℎ1 − ℎ퐸푃퐶 + ꢀ푊  
EJEEE 2026  
3 of 8  
900  
800  
700  
600  
500  
400  
300  
200  
100  
0
0
50  
100  
150  
200  
250  
300  
Normal exhaust volume flow  
Figure 1. Diagram of the simulated DSP station  
Figure 2. Its standard daily brightness  
Based on climate information from the Meteonorm database structure, a second gas-  
fired engine is activated when the steam flow rate is less than one-third of the design value  
to prevent power station closure throughout the evening. Because of reduced sinusoidal  
expenses, Figure 3 exhibits a rise in solar irradiation throughout the summer, when PTC  
may capture a sizable portion [11].  
0.9  
0.8  
0.7  
0.6  
0.5  
0.4  
0.3  
0.2  
0.1  
0
Figure 4. Illustration of the DSP station's hourly model-  
Figure 3. Mean monthly sunlight in Iraq  
ing process in Iraq [12]  
2.2 Technique and parameters of the experiment  
In the context of Iraq, a thorough modeling of the DSP solar field was developed for  
both linear Fourier collections and parabola dips. The first method uses a custom algo-  
rithm that calculates both the pressure drop and solar field steam generation based on  
the required quality of steam and solar radiation. The latter makes it possible to incorpo-  
rate sophisticated control techniques like narrowing and turning on the second boiler at  
evening. Using an iterative method, the two programs collaborate to offer an initial esti-  
mate of the solar field performance Figure 4.  
To prevent a power station, collapse at nighttime, an auxiliary gas-fired boiler acti-  
vates when the velocity of steam falls below one third of the intended level (8.5 kg/s),  
therefore maintaining a minimum steam flow rate of 2.8 kg/s.  
The referred to location is Madrid. The annual DNI for the location is 1625 kWh/m2,  
based on meteorological data from the Meteonorm dataset. Figure 3 demonstrates a rise  
EJEEE 2026  
4 of 8  
in solar radiation during the summer months, when PTC may capture a substantial por-  
tion of the DNI, owing to reduced sinusoidal costs.  
3. Results  
A comprehensive model of the DSP solar field was developed for both parabolic  
troughs and linear Diffraction collectors inside a combined Octave setting. In the previous  
instance, a custom algorithm calculates the steam output as well as the drop of the solar  
surface, contingent upon the solar rays and the required vapor grade. The last feature  
permits the incorporation of complex control schemes, involving the activation of the aux-  
iliary boiler at nighttime and refocus. Both projects cooperate to provide a preliminary  
assessment of the sun's radiation efficiency via an iterative procedure Figure 4.  
Temperature input and velocity equilibria were verified at each dx. The controlling  
parameters are the liquid speed in the heater and the energy value in the evaporator/su-  
perheater. The X-Steam utility facilitated the calculation of thermal characteristics of wa-  
ter and steam under all conditions of heat, pressure, and steaming condition.  
Furthermore, concentrated and dispersed pressure losses were calculated for both  
one-phase and two-phase modules independently, as recommended by [13]. Concen-  
trated losses consider four conventional 89° elbows, while dispersed effects are computed  
at each differential segment, because they involve shearing loss across the whole length  
of the module. In two-phase circulation, pressure losses are amplified by an amount de-  
pendent upon steam reliability, as shown by [13, 14]. The Matlab code produces results  
for pressure and temperature at the solar field exit, which are displayed alongside the  
steam rate of flow provided. The last parameter undergoes additional modification: if  
pressure and temperature surpass the maximum flow rate thresholds, focusing is initi-  
ated; conversely, if pressure and temperature fall below the lowest possible flow rate, the  
second boiler turns on and use of fossil fuels is considered (refer to Figure 4). The reader  
is directed to [15] for a comprehensive account of the formulas used in the solar field  
model. This research excludes thermal power storing. Focusing has been disabled.  
Yearly numerical simulations have been conducted to assess the efficiency of the DSP  
plant during various turbine operational conditions. Outcomes are given by concentrating  
on a representative both summer and winter workday to examine the intricacies of part-  
load performance. Subsequently, data from one-year models are juxtaposed to assess the  
influence of turbine operational modes on power production and solar-to-electric perfor-  
mance.  
3.1. Hourly Modeling Outcomes  
Climatic circumstances regarding the outside temperature and DNI patterns are  
shown in Figures 5a and 5b for the chosen days: one in winter, on November 15th, and  
one in summer, June 15th. The minimum outside temperature is around 5°C in winter,  
while the maximum temperature reaches 51°C during summer afternoons, coinciding  
with a peak Direct Normal Irradiance (DNI) of 750 W/m². In November, the peak sun  
radiation is restricted to 640 W/m². Figures 6a and 6b illustrates the total electrical power  
and total electric performance of the DSP, calculated as the proportion of total power pro-  
duction to solar heat input. Four patterns are shown throughout time to accommodate  
winter and summer climates as well as throttle and sliding turbine settings.  
EJEEE 2026  
5 of 8  
January  
July  
January  
July  
1200  
1000  
800  
600  
400  
200  
0
60  
50  
40  
30  
20  
10  
0
0
5
10  
15  
20  
25  
0
5
10  
15  
20  
25  
Time in Hours  
Time in Hours  
Figure 5a. Temperature of the day  
January July  
Figure 5b. Sunlight exposure per day  
January July  
7
6
5
4
3
2
1
0
3
2.5  
2
1.5  
1
0.5  
0
0
5
10  
15  
20  
25  
0
5
10  
15  
20  
25  
Time in Hours  
Time in Hours  
Figure 6a. Gross energy usage per day  
Figure 6b. Use of fossil fuels  
Beginning from left to right, the total energy curves indicate that the intended power  
point of 6 MWe was surpassed for 10 hours on June 15th. In November, the power pro-  
duction is consistently below fifty percent of the rated amount throughout the day.  
The causes for this are associated with the elevated sunlight and high visibility dur-  
ing summer, contrasted with the diminished solar energy and suboptimal performance  
during winter. The proportion of solar radiation captured decreases in winter due to its  
cosine impact and reduced temperature outside.  
The beneficial impact of the sliding setting on total energy performance, compared  
to the accelerator setting, during midnight at minimal load usage results in a productivity  
increase of up to 2%; during daytime hours, the enhancement in performance is below  
2%. The decreased effectiveness of the accelerator state under partial load is attributable  
to choking losses in the high-pressure turbine phase. The restriction diminishes the gen-  
eral effectiveness of the HP turbine when the steam flow rate falls below the intended  
threshold. In contrast, the sliding operation maintains a nearly constant total turbine out-  
put at the design value, regardless of the steam flow rate Figure 7.  
EJEEE 2026  
6 of 8  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
Throttle  
Sliding  
1.1  
1
0.9  
0.8  
0.7  
0.6  
0.5  
0.4  
1
3
5
7
9
11  
13  
Time in Hours  
Figure 7. The total efficiency of an HP rotor  
Figure 8. Median total energy production per month.  
Concentrating on the sliding mode, it is noteworthy that on the chosen days, the per-  
centage consistently remains below the design threshold (24%) during periods of intense  
solar radiation and moderate temperatures. A greater quantity of solar energy is accessi-  
ble at elevated ambient temperatures, hence diminishing the effectiveness of the ranked  
cycle to around 24%. It is well recognized that heat dissipation to air in a dry cooling sys-  
tem is crucial during hot weather. During winter, low temperatures combined with weak  
steam output result in 24% at 12 hours. During nightfall, the plant's performance at mini-  
mal load is only influenced by the outside temperature, which is three percent greater on  
winter days.  
3.2. Yearly Modeling Outcomes  
Figure 8 illustrates the typical monthly total power generation for both turbine set-  
tings. The sliding phase guarantees increased total energy production consistently during  
every season, particularly during winter months when the plant works at partial load con-  
tinuously. Figure 8 illustrates the total energy effectiveness of the DSP performances for  
each hour of the entire year, correlated with DNI. Values of DNI below 360 W/m2 were  
excluded owing to severe off-design situations. A second-degree quadratic was deter-  
mined to be the optimal estimate for both blade speeds. A limit of 24.1% is attained for  
accelerator setting.  
Table 3. DSP operations on an annual basis.  
Throttle mode  
Sliding mode  
Electricity Gross energy (MWh/day)  
Gross energy performance on average (%)  
Mean level at the turbine's intake (bar)  
Annual usage of fossil fuels (kg/h)  
53.1  
18.2  
73.8  
501  
53.6  
19.1  
74  
504  
The outcomes of the yearly experiments are encapsulated in Table 3. In comparison  
to the accelerator setting, the sliding selection yields about 6% more total electrical power  
annually, accompanied by an enhanced average total efficacy (19.7% against 21.3%). The  
mean turbine intake pressure is around fifty percent of the intended amount, so indicating  
that the DSP generator works at partial capacity for the majority of every year.  
The sole drawback of sliding operation is a marginal increase in the use of fossil fuels  
(+3.3%), attributed to the elevated entropy of the hot steam reaching the high-pressure  
EJEEE 2026  
7 of 8  
turbine; the heated steam maintains the same temperature as in accelerator function but  
operates at reduced pressure ranges. This disadvantage mostly manifests at nighttime.  
5. Conclusions  
A modeling approach using three distinct simulation platforms, including MATLAB,  
has been employed to predict the performance of a 6MWe DSP solar power plant, devel-  
oped under the INDITEP program. The coexistence of different codes allowed the user to  
take the best from each programming language. Specifically, it is the most appropriate  
platform for addressing transient irradiation intervals; it additionally excels in forecasting  
energy unit performance under partial load while adeptly handling the specifics neces-  
sary for DSP solar environment modeling. Annual models with a one-hour time increment  
were conducted for two distinct operational modes of the HP steam turbine, namely "slid-  
ing" and "acceleration" inlet temperature. The sliding mode yielded a 6% increase in net  
power generation and a 10% enhancement in net power performance annually, as com-  
parison to the throttle mode. The only disadvantage is a 3.1% increase in energy use.  
EJEEE 2026  
8 of 8  
References  
1.  
2.  
Ravelli, S., et al., Modeling of direct steam generation in concentrating solar power plants. Energy Procedia, 2016. 101: p. 464-471.  
Montes, M., A. Abánades, and J. Martínez-Val, Thermofluidynamic model and comparative analysis of parabolic trough collectors  
using oil, water/steam, or molten salt as heat transfer fluids. 2010.  
3.  
Martínez, I., et al., Annular Two-Phase Flow Regimen in Direct Steam Generation for a Low-Power Solar System, in Experimental  
and Computational Fluid Mechanics. 2013, Springer. p. 157-174.  
4.  
5.  
Chiarappa, T., Performance of direct steam generator solar receiver: laboratory vs real plant. Energy Procedia, 2015. 69: p. 328-339.  
Seitz, M., P. Cetin, and M. Eck, Thermal storage concept for solar thermal power plants with direct steam generation. Energy  
Procedia, 2014. 49: p. 993-1002.  
6.  
7.  
8.  
Pal, R.K. and R. Kumar, Investigations of thermo-hydrodynamics, structural stability, and thermal energy storage for direct steam  
generation in parabolic trough solar collector: a comprehensive review. Journal of Cleaner Production, 2021. 311: p. 127550.  
Bandaru, S.H., et al., A general framework for multi-criteria based feasibility studies for solar energy projects: Application to a real-  
world solar farm. Energies, 2021. 14(8): p. 2204.  
Wu, J., et al., Operation strategy and capacity configuration of digital renewable energy power station with energy storage. Heliyon,  
2024. 10(15).  
9.  
Zarza, E., et al., INDITEP: The first pre-commercial DSG solar power plant. Solar energy, 2006. 80(10): p. 1270-1276.  
Graciano, D., et al., Damage evaluation and life assessment of steam turbine blades. Theoretical and Applied Fracture Mechanics,  
2023. 124: p. 103782.  
10.  
11.  
12.  
13.  
14.  
15.  
Escandón, R., et al., How do different methods for generating future weather data affect building performance simulations? A  
comparative analysis of Southern Europe. Buildings, 2023. 13(9): p. 2385.  
Talal, W. and A. Akroot Exergoeconomic Analysis of an Integrated Solar Combined Cycle in the Al-Qayara Power Plant in Iraq.  
Processes, 2023. 11, 656 DOI: 10.3390/pr11030656.  
Akba, T., D. Baker, and A.G. Yazıcıoğlu, Modeling, transient simulations and parametric studies of parabolic trough collectors with  
thermal energy storage. Solar Energy, 2020. 199: p. 497-509.  
Khoshrou, I., M.J. Nasr, and K. Bakhtari, New opportunities in mass and energy consumption of the Multi-Stage Flash Distillation  
type of brackish water desalination process. Solar Energy, 2017. 153: p. 115-125.  
Ramde, E.W., et al., Pilot low-cost concentrating solar power systems deployment in Sub-Saharan Africa: a case study of  
implementation challenges. Sustainability, 2020. 12(15): p. 6223.