EJEEE 2025, Vol.3 47 of 64
The novel grid-codes recommended remaining the wind-turbines connected to the grid
in the presence of voltage-dips by improving their performance under transient states [3].
Voltage-dip makes the wind turbines (WT) system interrupted frequently. For the large
WT systems, the interruption leads to preventing the grid from multi-megawatts of power
[4]. Previously, the level of WTs penetration was small compared with classical generation
units [5], thus the WTs disconnections from the grid are allowed under voltage-dips to
prevent the negative effects. Nowadays, the WTs penetration is obviously increased in the
power system. Several researchers provide fault ride-through strategies. Some of these
strategies improve the performance partially, and the others improve the performance
completely. Several researchers tried to combine these strategies to provide powerful per-
formance. A traditional crowbar protection is applied to protect the RSC against asym-
metric and symmetric voltage, the Vdc of the DC-Link is improved at the asymmetric
type, but there is no improvement to the rest of the parameters for other types of faults
[6]. Under voltage-dip, this crowbar provides a path to allow the over-currents to pass
through. In this case, the crowbar disconnects the RSC to protect it from the over-currents
and this is considered the major disadvantage of this scheme [7]. When RSC is discon-
nected, the DFIG changes to a squirrel cage induction generator and receives reactive
power. Additionally, Crowbar protection requires a suitable instant to be deactivated.
This is necessary to decrease the consumption of reactive power and recover the DFIG
control as mentioned in [8], the results explained that only rotor-current and dc voltage
are improved under symmetric faults, the researcher did not treat the other types of faults.
Additionally, the torque ripples are not taken into consideration. Ref [9] studied DFIG
performance with the crowbar circuit under only a symmetric dip. The selected protection
did not improve the rotor-current and other DFIG parameters. Ref [10] used STATCOM,
that is installed on the grid-side converter, sharing with a super-capacitor which is in-
stalled on the DC-Link to enhance the DFIG performance. The outcomes illustrated that
STATCOM reduced only the peak of Vdc but did not mitigate the ripples, the method is
tested only for asymmetric dip. Ref [11] Compared between SVC, STATCOM, SDSC tech-
niques to mitigate the fault effects, these methods are tested for only symmetric-dips. The
results showed that SVC and STATCOM reduced the overvalues of the Vdc and rotor-
currents, but they have not reduced the oscillations. The SDSC improved the DFIG's pa-
rameters and mitigated the ripples. Ref [12] Applied DVR circuit sharing with synchro-
nous-reference frame control approach to compensate for the voltage-dip on the DFIG
stator, the method is only applied for the asymmetric-dip. This method proved its ability
to reduce the overcurrent and mitigate the Tem's ripples. Ref [13] Investigated the DVR
performance to compensate the symmetric-dip based on several control schemes; the
studied schemes did not mitigate the ripples. Ref [14] Proposed DVR based on active-
disturbance rejection control to enhance the LVRT needs; only the symmetric case is stud-
ied and also in this case, the torque's oscillations are not cancelled.
Problem of study:
From previous studies, it is found that each of them used a method to treat one type
of fault without the rest of the types such as [8, 10, 13], and in each of these studies some
parameters were improved. For example, ref [13] improved the current but did not men-
tion the torque, and some of them reduced the capacitor voltage but did not eliminate the
oscillations, and the rest of the studies are the same. Additionally, those methods also
neglect the shifting from generator to power consumer in some severe fault conditions.
Therefore, since the electrical grid is vulnerable to multiple types of faults, an effec-
tive method must be employed to ensure optimal generator performance. This minimizes
fault currents, protects the rotor windings and the RSC, and maintains the nominal values
of both the capacitor voltage and electromagnetic torque. Furthermore, many studies have
not addressed the problem of torque ripples, nor have they addressed the problem of the
machine's shifting from power delivery to power consumption from the grid during
faults. Based on the above, this study designed a DVR that integrates with ANFIS control-
lers, which are trained on a wide range of grid data. This enables it to adapt to all possible